A cavity exposed while machining a bronze impeller does not automatically contradict an earlier penetrant result. Before material was removed, that cavity could have been completely enclosed. Penetrant needs an opening at the examined surface.
For an OEM buyer, the useful question is therefore more precise than “Has the casting been NDT tested?” It is: which condition was examined, in which region, at which manufacturing stage?
A penetrant result has a surface boundary
Liquid penetrant testing, often called dye penetrant testing or PT, uses a liquid that enters surface-opening discontinuities and produces an indication during examination. The National Board's explanation of penetrant examination includes bronze among the nonporous materials that can be examined.
An enclosed internal cavity has no route for that liquid to enter. A satisfactory PT result consequently does not demonstrate that the metal beneath the surface is free of enclosed discontinuities.
Access and surface condition matter as well. Contamination or an obstructed opening can interfere with the method. An inaccessible internal passage is not covered simply because the report identifies the whole impeller by one part number. The report needs to make its examination region understandable.
This is also why a general photograph and a penetrant record serve different purposes. The photograph can locate a feature; it does not establish that an examination reached every surface visible somewhere inside the part.
Radiography asks an internal question
Radiographic testing, RT, forms images using X-rays or gamma rays passing through the component. It can provide evidence about internal structure that a surface-opening method cannot. ASNT's radiographic-testing guide describes both film and digital approaches.
An RT result still has limits. Geometry, access and the orientation of a discontinuity relative to the beam affect detection. “X-rayed” is not a guarantee of zero discontinuities or proof that every possible location and orientation was examined.
For a hub or shroud region under review, connect the image or report to that region. Without a location reference and the applicable examination basis, a buyer cannot tell whether the supplied image answers the concern that prompted the inspection.
On a small screen, scroll the table sideways.
| Evidence supplied | Question it can address | Conclusion to avoid |
|---|---|---|
| Penetrant examination of identified surfaces | Relevant surface-opening indications under the stated examination conditions | The entire internal volume is free of cavities |
| Radiographic examination of identified regions | Internal conditions visible with the stated technique and image coverage | Every discontinuity, however small or oriented, would be detected |
| A report disposition such as “accepted” | Conformance to the criterion applied to that examination | Every other drawing requirement has also passed |
Read the manufacturing stage before the verdict
Consider a casting supplied with extra material on a hub face. A cavity below that face is enclosed at the casting stage. Removing the extra material can expose it at the finished surface. The part has reached a different condition, so the earlier surface result and the later observation describe different boundaries.
That sequence explains how the findings can coexist. It does not identify whether the cavity arose from gas, shrinkage or another mechanism, and it does not establish whether it is acceptable. The porosity-after-machining guide addresses the manufacturing decisions that follow a newly exposed opening.
The ICI's 2024 buyer-oriented conference discussion also distinguishes inspection and machining considerations, including the limits of partial sampling. Use that as a reason to define the inspected stage and coverage, rather than assuming that one successful sample represents an unspecified lot.
Specify the evidence you need to receive
Method selection and acceptance are separate decisions. Naming PT or RT does not set the permitted indication type, size or location. Those criteria must come from the governing drawing, specification or agreed inspection requirement.
A useful inspection record connects the part identity, examined area, manufacturing condition, method or technique, and acceptance reference. An unexplained “passed” leaves the buyer reconstructing those relationships.
For a closed impeller, use the internal-passage inspection guide to separate access and visual coverage from internal-metal examination. These methods do not become interchangeable because all are described as inspection.
When preparing a bronze impeller enquiry through the product page, include the marked inspection region and the requirement identifying the casting or finished-part stage. That places the requested evidence against the part being purchased, before a test name becomes an undefined promise in the order.